Air Conditioning versus Air Source Heat Pump

May 15, 2021

Click for a larger version. Similarities and differences in how an air source heat pump (ASHP) or an air conditioning (AC) system warms a home. All the components inside the dotted green line are contained in the external units shown. A key design difference is whether or not the working fluid is completely contained in the external unit. See text for more details.

Regular readers will probably be aware that – having reduced the heating demand in my house – my plan is to switch away from gas heating and install an electrically-powered air source heat pump to heat the house and provide domestic hot water.

But next week I am also installing air conditioning, something which is traditionally not thought of as very ‘green’. What’s going on?

Why Air Conditioning?

I have two reasons.

My first reason is that, as you may have heard, the whole world is warming up! Last year it reached 38 °C in Teddington and was unbearably hot for a week. I never want to experience that again.

During the summer the air conditioning will provide cooling. But assuming the heating comes with good weather, the air conditioning will be totally solar powered, and so it will not give rise to any CO2 emissions to make matters worse!

My second reason is that in the right circumstances, air conditioning is a very efficient way to heat a house. That’s what this article is about.

Heat Pumps

Air Conditioners (AC) and Air Source Heat Pumps (ASHP) are both types of heat pumps.

In scientific parlance, a heat pump is any machine that moves heat from colder temperatures to higher temperatures at the expense of mechanical work.

Note: to distinguish between the general scientific idea of a heat pump, and the practical implementation in an air source heat pump, I will use abbreviation ASHP when talking about the practical device.

The general idea of a heat pump is illustrated in the conceptual schematic below.

As shown, the pump uses 1 unit of mechanical energy to extract two units of heat energy from air at (say) 5 °C and expel all 3 units of energy (1 mechanical and 2 thermal) as heat into hot water at (say) 55 °C.

Click for a larger version. Traditional representation of the operation of heat pump.

Heat pumps can seem miraculous, but like all good miracles, they are really just applied science and engineering.

A heat pump is characterised using two parameters: COP and ΔT.

  • A heat pump which delivers 3 units of heat for 1 unit of work is said to have a coefficient of performance (COP) of 3.
  • The temperature difference between the hot and cold ends of the heat pump is usually called ‘Delta T’ or ΔT.

Obviously engineers would like to build heat pumps with high COPs, and big ΔTs and they have used all kinds of ingenious techniques to achieve this.

But it turns out that heat pumps only operate with high COPs when the ΔT is small and when the heating power is low. There are two reasons.

  • Firstly, the laws of thermodynamic set some absolute limits on the COP achievable for a given ΔT.
    • Most practical heat pumps don’t come close to this thermodynamic limit for a variety of mundane reasons.
    • The maximum COP for moving heat from 5 °C to 55 °C is 6.6.
    • The maximum COP for moving heat from 5 °C to 20 °C is 19.5.
  • Secondly, in order to heat a room to (say) 20 °C, the hot end of the heat pump needs to be hotter than 20 °C.
    • Typically the hot end of the heat pump must be 5 °C to 10 °C warmer than the room in order that heat will flow out of the heat pump.
    • Additionally the cold end of the heat pump must be 5 °C to 10 °C colder than the external air in order that heat will flow into the heat pump.
    • The interfaces between the ends of the pump and the environment are called heat exchangers and designing ‘good’ heat exchangers is tricky.
    • A ‘good’ heat exchanger is one that allows high heat flows for small temperature differences.

So now we have seen how heat pumps are characterised, let’s see how heat pumps are used domestically.

Air Source Heat Pump (ASHP) versus Air Conditioner (AC)

The schematic diagrams  below show how a house is heated by an ASHP and an AC system. Both systems operate using a working fluid such as butane, which is ingeniously compressed and expanded. The details of this process are not the topic of this article so here I am glossing over the fascinating details of the device’s operation. Sorry.

Click for a larger version. How an air source heat pump (ASHP) warms a home. All the components inside the dotted green line are contained in the external unit shown. A key design feature is that the working fluid is completely contained in the external unit and heat is transferred to the central heating water by a heat exchanger.

Click for a larger version. How an air conditioner (AC) warms a home. All the components inside the dotted green lines are contained in either the external unit or the fan coil unit shown. A key feature is that the working fluid itself flows into the fan coil unit and heats the air directly.

We can compare the operation of the two systems in the table below.

Air Conditioner Air Source Heat Pump
Air at (say) 5 °C is blown over a heat exchanger and evaporates the working fluid.

 

The same.
The working fluid is then compressed – that’s the bit where the work is done – and liquefies, releasing the captured heat.

 

The same.
The hot working fluid – now at ~30 °C then flows through a pipe to an indoor heat exchanger (fan coil unit) where air is blown over the pipe and heated to 20 °C. The hot working fluid – now at ~60 °C then flows through a heat exchanger and transfers the heat to water in my central heating system at ~55 °C
No corresponding step  

The 55 °C water then flows through a radiator in my room, heating the room by radiation and by convective heat transfer to air at ~20 °C.

Looking closely at the figures and table above, one can see that the operation of the ASHP and the AC system are broadly similar.

However the ASHP has to operate with a bigger ΔT (~55 °C versus ~25 °C) than the AC system, and also has to transfer heat through an extra heat exchanger.

Both these factors degrade the achievable COP and so for my application, the specified COP for an ASHP is just over 3, but for the AC system, it is just over 5.

In my well-insulated house, when the external temperature is 5 °C, I require typically 36 kWh per day of heating, equivalent to 1.7 kW continuous heating. I can achieve this in several ways:

  • Using gas I must burn ~40 kWh of gas at 90% efficiency costing 40 x 3p (£1.20) and emitting 40 x 200 g = 8 kgCO2
  • Using an ASHP with a COP of 3, I must use ~36 kWh/3 = 12 kWh of electricity costing 12 x 25p (£3.00) and emitting 12 x 200 g = 2.4 kgCO2
  • Using an AC system with a COP of 5, I must use ~36 kWh/5 = 7.2 kWh of electricity costing 7.2 x 25p (£1.80) and emitting 7.2 x 200 g = 1.4 kgCO2
  • Using a domestic battery and buying the electricity at night for 8p/kWh, I can reduce the cost of using an ASHP or AC system by a factor of 3 to £1.00/day or £0.60/day respectively.

[Note: In these calculations I have assumed that the carbon dioxide emissions per kWh are same for both gas and UK electricity (200 gCO2/kWh) which is roughly correct for 2021]

So using an AC system I should be able to achieve domestic heating with lower carbon dioxide emissions than an ASHP.

My plan

In my case I need to heat water for my home to 55 °C for use in showers and basins. So I need an ASHP for that. And since I already have radiators in every room, hooking up the ASHP to the radiator circuits is smart double use.

The AC system I am having installed will have 1 external unit and 2 internal ‘fan coil units’. One unit will be in my bedroom (a sheer indulgence) and the other will be high up on the stairs, allowing air to be either blown down to the ground floor where I hope it will circulate, or blown towards the bedrooms.

My hope is that, when used together, the AC system (COP~5) will reduce the heating output required from the radiators so that I can reduce the flow temperature of the water from 55 °C to perhaps 40 °C. This reduces their heat output, but increase the COP of the ASHP from 3 to perhaps 4.

The main difficulty that I foresee is the extent to which the AC heating will actually permeate through the house and so reduce the amount of heating required by the ASHP.

So I am not sure how much heating will be required by the ASHP acting through the radiators, and whether the radiators will work at low flow temperatures. It is possible I might need to replace a few radiators with ones which work better at low temperatures.

It is not at all obvious that this plan will actually work at all – but I think it is worth a try.

Kit

The air conditioning I am having installed is a Daikin 2MXM40 multi-split outdoor unit with two FTXM25 indoor air units. (Brochure)

The model of heat pump I will have installed is a Vaillant Arotherm plus 5 kW. It can supply up 5 kW of heating at 55 °C with a COP of 3  – i.e. it will use just 1.6 kW of electrical power to do that – and heat water to 55 °C. Water storage will be a 200 litre Unistor cylinder. A brochure with technical details can be found here, and a dramatic video showing the kit is linked at the end of this article.

When I have come to terms with how much money I am spending on this, I will share that information. But at the moment it hurts to think about it!